Sign In | Join Free | My wpc-board.com
wpc-board.com
Products
Search by Category
Home > Gloves & Mittens >

Thermal Shock Environment Electrical Test Equipment IEC60068-2-3 12 Months Warranty

Categories Environment Test Equipment
Brand Name: PEGO GROUP
Model Number: PG-TSC
Certification: CE Certificate
Place of Origin: China
MOQ: 1 set
Price: USD10000~USD15000
Payment Terms: T/T, Western Union, MoneyGram
Delivery Time: 30 working days
Packaging Details: woodencase
Standard: MIL STD,GB,JIS,JEDEC,IEC60068-2-3
Type: three box type
Thermal shock range: -40℃~ +120℃
Material: stainless steel
Size: 60L, 80L, 100L, 120L (optional)
Warranty: 12 months
Working Power: AC380V, 50HZ
Control system: TEMI880N+LCD touch screen
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Thermal Shock Environment Electrical Test Equipment IEC60068-2-3 12 Months Warranty

    IEC60068-2-3 Thermal Shock Environment Test Equipment from -40℃ to +120℃


    1. Introduction

    The thermal shock test chamber is divided into two-box type and three-box type. The difference is that the test method and internal structure are different. The product conforms to the standard: GB/T2423.1-2008 test A, GB/T2423.2-2008 test B, GB- T10592-2008, GJB150.3-198, GJB360A-96 Method 107 Requirements for temperature impact test. The thermal shock test chamber is an indispensable test equipment for the metal, plastic, rubber, electronics and other materials industries. It is used to test the degree to which a material structure or composite material can withstand in a transient environment of extremely high temperature and extremely low temperature. It is possible to detect chemical changes or physical damage caused by thermal expansion and contraction in the shortest time.


    Standard:MIL STD,GB,JIS,JEDEC,IEC60068-2-3


    2. Parameters:

    ● High temperature range: +80℃~ +200℃

    ● Low temperature range: -10℃~ -60℃

    ●Temperature cyclic range: -40℃~ +120℃

    ● Accuracy: ±2℃

    ● Resolution: 0.01℃

    ● Rising time at hot space: RT~150℃ <40mins

    ● Rising time at cold space: RT~-40℃ < 50mins

    ● Recover time at test space (-40℃~+120℃): 3~5 mins

    ● Weight of EUT: 5kg above

    ● Construction: high temperature chamber, low temperature chamber, test chamber

    ●Size option:

    Interior SizeW*D*H(mm)
    60L500*300*400
    80L400*400*500
    100L500*400*500
    150L500*500*600
    3. Features

    ●Thermal insulation material:High-density glass wool and high strength PU foamed insulation

    ● High-low temperature automatic switching equipment

    ● Power supply: 3 phase 5 wires (AC380V, 50HZ)

    ● Workin conditions requred: 0℃~35℃, ≤85%R.H

    ● Equipment consists by: high temperature chamber, low temperature chamber, test chamber, control system, cooling system, heating system, air duct system, drainage system

    ● Control system: TEMI880N+LCD touch screen


    4. Working Pricinple:

    A. Low temperature storage room: The temperature state inside the tank is determined by the working state of the heater, evaporator and fan in the air duct. After the refrigerant flowing out through the expansion valve enters the evaporator in the working chamber, the heat in the working chamber is absorbed and vaporized, so that the temperature of the working chamber is lowered; the working fluid after gasification is sucked by the compressor and compressed into high temperature and high pressure gas into the condenser. The medium is condensed into a liquid, and after being screened, finally throttled by the expansion valve, and then re-entered into the evaporator of the working chamber to absorb heat and vaporize and then be sucked and compressed by the compressor. So reciprocating loop work, the studio temperature is lowered to the set temperature requirements.


    B. High-temperature storage room: The central controller detects the instantaneous signal from the temperature-sensing component, compares it with the set temperature signal, and obtains the comparison signal. The output of the instrument PID logic circuit controls the turn-on or turn-off time of the solid-state relay to adjust the heater output power. In order to achieve the purpose of automatic temperature control.


    C. Impact temperature test chamber: The high and low temperature air valve is automatically controlled by the meter, and is switched between the low temperature or high temperature storage chamber, and a closed circuit air circulation system is formed respectively with the high temperature box or the low temperature box to quickly reach the target temperature of the test.


    The temperature state in the test chamber is determined by the operating conditions of the heater, evaporator, and fan in the duct. The working chamber of the test box adopts the forced axial flow “scattering” type loop wind operation, which can greatly improve the parameters such as fluctuation and uniformity of equipment operation.

    Quality Thermal Shock Environment Electrical Test Equipment IEC60068-2-3 12 Months Warranty for sale
    Send your message to this supplier
     
    *From:
    *To: Pego Electronics (Yi Chun) Company Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0