Sign In | Join Free | My wpc-board.com
wpc-board.com
Products
Search by Category
Home > Plastic Products >

Insulation Resistance Tester |Compact Insulation Resistance Meter for On-site Electrical Test Work

Categories Cable Fault Locator
Certification: ISO,CE
Brand Name: XZH TEST
Price: Negotiable
Place of Origin: Xi'an, Shaanxi, China
MOQ: 1 unit
Supply Ability: 2000units/year
Data Storage: 500 sets; a flashing "FULL" symbol indicates that storage capacity is full.
USB Interface: Equipped with a USB interface
Withstand Voltage: AC 3kV / 50Hz for 1 minute
Delivery Time: 8-10 days
Payment Terms: T/T
Instrument Dimensions (L×W×H): 240mm × 188mm × 85mm
LCD Display Size: 108mm × 65mm
Model Number: XHMR-5000A
Packaging Details: wooden packaging
Communication Cable: 1 × USB communication cable
Test Leads: Red high-voltage probe (3m), Black high-voltage test lead (1.5m), Green lead (1.5m)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Insulation Resistance Tester |Compact Insulation Resistance Meter for On-site Electrical Test Work

1. Introduction

The insulation resistance tester—also known as a megohmmeter, high-voltage insulation resistance tester, etc.—is used for measuring insulation resistance.

2. Voltage Ranges and Accuracy
Measurement FunctionMeasurement RangeAccuracyResolution
DC VoltageDC 0.0V – 1000V±1.5% rdg ±3 dgt0.1V
AC VoltageAC 0.0V – 750V±1.5% rdg ±3 dgt0.1V
3. Technical Specifications
FunctionsInsulation Resistance Test, Voltage Test, DC Current Test, Capacitance Test
Reference Conditions23°C ±5°C, <75% RH
Rated Voltage100V, 250V, 500V, 1000V, 2500V, 5000V
Insulation Resistance Range0.01 MΩ – 10 TΩ | Resolution: 0.01 MΩ
Rated Voltage250V, 500V, 1000V, 2500V, 5000V, 10 kV
Insulation Resistance Range0.01 MΩ – 35 TΩ | Resolution: 0.01 MΩ
Rated Voltage500V, 1000V, 2500V, 5000V, 10 kV, 15 kV
Insulation Resistance Range0.01 MΩ – 50 TΩ | Resolution: 0.01 MΩ
Measurement Voltage (V)Rated Voltage × (1 ±10%)
DC Voltage Range0 – 1000V | Resolution: 0.1V
AC Voltage Range0 – 750V | Resolution: 0.1V
DC Current0.1 nA – 6 mA | Resolution: 0.1 nA
Capacitance10 nF – 50 µF | Resolution: 10 nF
Output Short-Circuit Current≥6 mA @ 15 kV
Absorption Ratio (DAR) and Polarization Index (PI) MeasurementSupported
Power Supply12.6V Rechargeable Lithium Battery
BacklightSupported Controllable gray-white screen backlight, suitable for use in dimly lit environments.
Display Mode4-digit extra-large LCD display with gray-white screen backlight.
4. Measurement Principle

Insulation resistance measurement utilizes a voltage generator to generate a voltage (V), which is applied across the resistor under test. By measuring the current (I) flowing through the resistor, the resistance value (R) is calculated using the formula R = V/I.

Safety Precautions:
  • In all circumstances, special attention must be paid to safety when using this instrument.
  • This instrument has been designed, manufactured, and tested in accordance with the IEC 61010 safety specifications.
  • In all circumstances, special attention must be paid to safety when using this instrument.
  • During measurements, do not use high-frequency signal generators—such as mobile phones—in the vicinity of the instrument, as this may introduce measurement errors.
  • Pay close attention to the text and symbols displayed on the labels affixed to the instrument's casing.
  • Before use, verify that the instrument and its accessories are in good condition; specifically, ensure that the insulation on the instrument and test leads is intact, with no exposed conductors or broken wires, before proceeding with measurements.
  • During the measurement process, strictly avoid touching exposed conductors or the circuit currently being tested.
  • Ensure that the connection plugs of the test leads are firmly inserted into the corresponding ports on the instrument.
  • Do not perform measurements in flammable environments, as sparks generated during operation could trigger an explosion.
  • If the instrument's casing or test leads become damaged—exposing internal metal components—while the unit is in use, immediately cease operation.
  • Do not leave or store the instrument for extended periods in environments characterized by high temperatures, high humidity, condensation, or direct sunlight.
  • When replacing the instrument's batteries, ensure that the test leads have been disconnected from the unit and that the instrument is powered off.
  • If the instrument displays the "Low Battery Voltage" symbol, recharge the unit immediately; failure to do so may result in measurement inaccuracies.
  • Strictly avoid performing charging or data transmission operations while a measurement is in progress.

Quality Insulation Resistance Tester |Compact Insulation Resistance Meter for On-site Electrical Test Work for sale
Send your message to this supplier
 
*From:
*To: Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0